2 HP 460V ADJUSTABLE FREQUENCY DRIVE, EATON # MVX002A0-4 Live Price: $390.00 Super Savings! Cutler-Hammer® MVX9000 sensorless vector adjustable frequency AC Drives from Eaton’s electrical business are designed to provide adjustable speed control of three-phase motors. These microprocessor-based, sensorless vector drives have standard features that can be programmed to tailor the drive’s performance to suit a wide variety of application requirements. * Overload Rating: 150% for 60 seconds * Frequency Resolution: Digital: 0.1 Hz, Analog: Max. (Set Frequency/1000) Hz * Frequency Accuracy Digital: ± 0.01% of max. frequency, Analog: ± 0.2% of max. frequenc * Undervoltage Carryover Limit: 0.3 to 25 seconds * Motor Control: Sensorless Vector * Constant and Variable Torque: Standard * Speed Regulation: 0.5% of base speed * Voltage at 50/60 Hz ± 3 Hz * Displacement Power Factor: Better than 0.95 * Efficiency: Typically greater than 95% * Inverter Type: Insulated Gate Bipolar * Waveform: Sensorless Vector * Operating Temperature: -10°C to +50°C; -10°C to +40°C (above 7-1/2 hp) * Humidity: 20 to 90% non-condensing * Maximum Elevation: 1000 meters (3300 ft.) * NEMA, IEEE, NEC: Design Standards * CE Marked (Requires EMI filter) * Standard: Protected Chassis (IP20) * Overload Protection: Standard * Set Up Adjustments, Performance * Features, Operator Control and * Alphanumeric Display: Standard, 1 x 4 character * Digital Indications: Frequency (Hz), Motor Current (amps), User-Defined RUN/STOP, * FORWARD/REVERSE and Parameters * Diagnostics: Last 3 trips with cause * (RUN/STOP, FORWARD/REVERSE, * Hz, Amps, User Defined, and Input Speed) * START/STOP, Speed control (digital * or potentiometer), RESET, SETUP * Analog Inputs: 2 Inputs: 0 – 10V DC, 4 – 20 mA; Potentiometer: 1K ohm to 2K ohm * Analog Voltage: Nominal 10V DC (10K ohm input impedance) * Analog Current: Nominal 4 – 20 mA (250 ohm) * Digital Inputs: 6 Programmable * Digital Outputs: 1 Programmable * Open collector and 1 Form C Relay contact * Analog Monitor Output: Analog meter – frequency or output current * Out of the Box: Factory settings loaded for quick start-up. * Accel. and Decel.: 2 separately adjustable Linear or S Curve times: 0.1 – 3000 seconds * Auto Restart: Overcurrent, overvoltage and undervoltage with 4 selectable retry restart modes * External Fault: Terminal input * Fault Reset: STOP/RESET or terminal input * Jump Frequencies: 3 (with adjustable width) * Parameter Security: Programmable software lock * Preset Speeds: 7 preset speeds * PID Controller: PID process control * Reversing: Keypad or terminal * Speed Setting: Keypad, terminal or pot * START/STOP Control: Keypad or terminal * Stop Modes: Decel, coast or DC injection * Pretested Components: Standard * Surface Mount Technology: Standard (PCBs) * Computerized Testing: Standard * Final Test with Full Load: Standard * Eaton’s Cutler-Hammer Engineering * Systems and Service: National network of AF drive specialist (all content is the responsibility of the poster) |
L.Kerr@oklahomaselltoday.com (Lonnie Kerr)
for more information. All emails will be forwarded to the poster's actual email address.